节点报告 StorageFCAdapterFault_Alert 出现故障或未使用的 FC 端口
适用于
- ONTAP 9
- MetroCluster
- FAS / AFF
- 以启动器模式运行的 FC 端口
问题
- 每次重新启动后,节点都会针对关闭的 FC 端口发送 AutoSupport StorageFCAdapterFault 警报:
Health Monitor process nchm: StorageFCAdapterFault_Alert[500##########]) ALERT.
- 报告的端口未使用
- MetroCluster_Node 子系统健康状况降级:
cluster::> system health subsystem show.
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node degraded
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
13 entries were displayed.
- 从 clustershell 中可以看到健康警报:
cluster::> system health alert show.
Node: node-01
Resource: 4d
Severity: Major
Indication Time: Sat Aug 15 13:05:58 2020
Suppress: false
Acknowledge: false
Probable Cause: FC initiator adapter 4d is at fault.
Possible Effect: Resiliency of backend storage is compromised.
Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
2. Verify the operational status of the FC initiator
adapter by using the command "system node run -node
local -command storage show adapter".