跳转到主内容

新 DS460C 机架显示琥珀色警示 LED 指示灯

Views:
14
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用于

DS460C 磁盘架

问题

  • 托架上的警示 / 故障指示灯呈琥珀色亮起
  • 可能会显示消息:"Event: monitor.globalStatus.critical: Disk shelf fault."
  • nodeshell 命令的输出 "torage show fault-v" 表示模块错误

 

Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : OK 01,00,01,00 REPORT
2 [IOM12 A] : OK 01,00,01,00 REPORT
3 [IOM12 A] : NONCRITICAL 03,00,09,00 REPORT, OPEN
4 [IOM12 A] : OK 01,00,01,00 REPORT
5 [IOM12 A] : OK 01,00,01,00 REPORT
6 [IOM12 B] : OK 01,00,01,00 REPORT
7 [IOM12 B] : OK 01,00,01,00 REPORT
8 [IOM12 B] : NONCRITICAL 03,00,09,00 REPORT, OPEN
9 [IOM12 B] : OK 01,00,01,00 REPORT
10 [IOM12 B] : OK 01,00,01,00 REPORT

  • sysconfig -输出可能会显示模块信息的不一致性

Shelf 5: DS460-12 Firmware rev. IOM12 A: 0250 IOM12 B: ----   <<-- 缺少固件版本

  • 未显示其它故障组件
  • 系统处于多路径 HA 中

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device