跳转到主内容

X336_HAKPE04TA07 型号的磁盘出现多个磁盘故障

Views:
40
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
hw
Last Updated:

适用场景

  • x336_HAKPE04TA07 NA00

问题描述

  • 同一 RAID 组中的两个以上磁盘发生预故障。示例:

Aggregate node_name_aggr1 (online, raid_dp) (block checksums)
  Plex /node_name_aggr1/plex0 (online, normal, active, pool0)
   RAID group /node_name_aggr1/plex0/rg0 (normal, block checksums) 
    RAID Disk Device   HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
    --------- ------   ------------- ---- ---- ---- ----- --------------   --------------
    ...
    data    0a.01.0P1 0a   1   0   SA: A   0  FSAS  7200 3752604/7685333504 3752612/7685349888 (prefail) 
    data    0a.01.1P1 0a   1   1   SA: A   0  FSAS  7200 3752604/7685333504 3752612/7685349888 (prefail) 
    data    0a.01.2P1 0a   1   2   SA: A   0  FSAS  7200 3752604/7685333504 3752612/7685349888 (prefail) 
    ...

  • 多个磁盘中的多个已恢复错误会触发磁盘故障: 

[node_name: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk 0a.01.0: op (...) sector 6 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 97 97)... 
[node_name: disk_server_0: disk.ioRecoveredError.pfa:error]: Recovered error predictive failure alert on disk 0a.01.0: op (...) sector 6 SCSI:recovered error - Disk reports predicted failure event (1 5d 90 90)
[node_name: disk_server_0: scsi.debug: debug]: shm_setup_for_failure disk 0a.01.0 (S/N AAAAAAAA) error 8000h

[node_name: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk 0a.01.1: op (...) sector 6 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 97 97)...
[node_name: disk_server_0: disk.ioRecoveredError.pfa:error]: Recovered error predictive failure alert on disk 0a.01.1: op 0x8f: 00000001cf0a2200:00000400 sector 6 SCSI:recovered error - Disk reports predicted failure event (1 5d 90 90)
[node_name: disk_server_0: scsi.debug: debug]: shm_setup_for_failure disk 0a.01.1 (S/N BBBBBBBB) error 8000h

[node_name: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk 0a.01.2: op 0x8f:00000001cce52200: 00000400 sector 5 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 97 97)...
[node_name: disk_server_0: disk.ioRecoveredError.pfa:error]: Recovered error predictive failure alert on disk 0a.01.2: op 0x8f: 00000001cce97600:00000400 sector 5 SCSI:recovered error - Disk reports predicted failure event (1 5d 90 90)
[node_name: disk_server_0: scsi.debug: debug]: shm_setup_for_failure disk 0a.01.2 (S/N CCCCCCCC) error 8000h

  • 在磁盘或其他存储硬件组件中未发现介质错误或其他不可恢复的问题。 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.