Effective December 3 - NetApp adopts Microsoft’s Business-to-Customer (B2C) identity management to simplify and provide secure access to NetApp resources. For accounts that did not pre-register (prior to Dec 3) access to your NetApp data may take up to 1 hour as your legacy NSS ID is synchronized to the new B2C identity. To learn more, Read the FAQ and Watch the video. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 

如何以最佳方式鉴别 "DIMM 映射出并显示错误 0x30 " 在各种 ONTAP 硬件平台上

Views:
22
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • AFF 系统
  • FAS 系统

解答

  • 错误输出示例

Initializing System Memory ...

DIMM:5 mapped out. BIOS MRC HW R/W test error. Major / Minor Error Code: 0x30 / 0x1C
Complete channel mapped out.

DIMM: B0 mapped out. BIOS MRC mapped out DIMM. Major Code 0x30 Minor Code 0x13

DIMM:2 mapped out. BIOS MRC HW R/W test error. Major / Minor Error Code: 0x30 / 0x1C
Complete channel mapped out.

  • 对于 0x30 错误,请确保系统正在运行最新的 BIOS * 之前 * 执行任何主板, DIMM 重新密封或更换。
平台 最小 BIOS 关联错误 指南
FAS9000/A700 10.5 1195242 知识库文章
FAS/AFF 80xx 9.7 1195423 知识库文章
FAS26xx , 8200 , 27xx , A300 , A220 , A200 11.5 1195243 知识库文章
A400 , FAS8300 , FAS8700 16.2 1302510 知识库文章
  • 您可以从控制台上的输出(在启动失败期间),维护模式下(使用 sysconfig -v)获取 BIOS 版本,也可以参考 sysconfig -a 输出中的最新 ASUP 数据
  • 如果在 ONTAP 升级期间发生这种情况,请执行 BIOS 更新并让升级继续正常进行
  • 如果系统未运行受支持的修复程序,请使用此操作步骤从加载程序更新 BIOS

其他信息

如果 BIOS 更新无法解决此问题,请联系NetApp 技术支持并参考此文章