跳转到主内容

即使更换闪存后,故障 LED 也不会关闭 缓存

Views:
14
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008696341</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS2720
  • ONTAP 9

问题描述

  • 即使在更换出现故障的Flash Cache之后、故障LED仍保持亮起状态。
  • "NVMe device failed"事件将在替换后保留。

  • 执行以下命令无法清除此错误事件。

 示例:

         ::> system controller service-event delete -node node-1 -event-id 1

::> system controller service-event show

 Node        ID  Event Location            Event Description
 ---------------- --- ----------------------------------  ----------------------
      node-01  1 Device in M.2 PCIe slot 1 in Controller A  NVMe device failed

  • 无法通过基板管理控制器(BMC)上的system fru led set off命令清除故障LED。

示例:

BMC> priv set diag
BMC*> system fru led set 15 off

========
FRU LEDs status
======================
<snip>
FRU LED ID 14 = BMC DIMM Slot 2 Attention LED
FRU LED ID 15 = BMC NVMEM 1 Attention LED
FRU LED ID 16 = BMC BOOT DISK Attention LED
<snip>
FRU LED ID 14 is off
FRU LED ID 15 is on 
FRU LED ID 16 is off

  • BMC重新启动无法解析问题描述。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.