跳转到主内容

NetApp_Insight_2020.png 

在环境关闭和机箱风扇更换之后出现 FAS9000 EMS 错误

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

FAS9000
ONTAP

问题

发生多风扇故障并导致环境关闭后、 EMS 消息表明风扇现场可更换单元在更换后仍继续出现故障。
 
cluster::*> event show -node local -event *fan*|*psu*
Time         Node        Severity    Event
------------------- ---------------- ------------- ---------------------------
10/25/2017 12:00:00 cluster
                   ALERT      monitor.fan.failed: Multiple fans has failed: FanA2 F4, FanA2 F3, FanA2 F2, FanA2 F1. <<<<<<<<<<<<<<<<< Generated when PSU 3 cable removed and inserted back after some time .
10/25/2017 11:52:00 cluster
                   EMERGENCY    monitor.globalStatus.critical: Controller failover of nbs-plat-9000-122 is not possible: Controller Failover takeover disabled. Multiple fans has failed: FanA2 F4, FanA2 F3, FanA2 F2, FanA2 F1.
10/25/2017 11:37:00 cluster
                   EMERGENCY    monitor.globalStatus.critical: Controller failover of nbs-plat-9000-122 is not possible: Controller Failover takeover disabled. Multiple fans has failed: FanA2 F4, FanA2 F3, FanA2 F2, FanA2 F1. Power Supply Status Critical: PSU3.
10/25/2017 11:09:00 cluster
                   EMERGENCY    monitor.globalStatus.critical: Controller failover of nbs-plat-9000-122 is not possible: Controller Failover takeover disabled. Multiple fans has failed: FanA2 F4, FanA2 F3, FanA2 F2, FanA2 F1.
10/25/2017 11:00:00 cluster
                   EMERGENCY    monitor.globalStatus.critical: Controller failover of nbs-plat-9000-122 is not possible: Controller Failover takeover disabled. Multiple fans has failed: FanA2 F4, FanA2 F3, FanA2 F2, FanA2 F1. Power Supply Status Critical: PSU1.
 

 