跳转到主内容

币形电池实时时钟(RTC)电池错误地报告低电压或高电压状态

Views:
81
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • AFF A900
  • AFF A700
  • AFF A220
  • AFF C190
  • FAS9000
  • FAS2750
  • FAS2720

问题描述

标识

请使用以下方法帮助确定此问题描述。

EMS事件日志

[node1: env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.

[NODE1:monitor.chassisPower.degraded:warning]: Chassis power is degraded: RTC Battery is in WARN LOW state current voltage is 2774 mV, normal low is 2800 mV
 

[env_mgr: monitor.rtcHighPower:error]: Real-time clock battery voltage is above normal (P3.3V Batt is warning high (3307 mV).)

[node1: env_mgr: monitor.rtcWarnLowPower:error]: Real-time clock battery voltage is below normal (2880 mV).

传感器状态
  • 3伏电池传感器将显示为警报状态:

cluster1::> system node environment sensors show -state !normal

Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
Bat 3.0V                critlow        2545 mV     2545 mV     2702 mV     3503 mV     3575 mV

或者:

P3V Batt         warnlow     2880 mV    2720 mV    2880 mV    3300 mV    3460 mV 

cluster1::> system controller service-event show

Node        ID  Event Location            Event Description
---------------- --- ----------------------------------  ----------------------
cluster1-01    1   Controller B on Chassis 1       P3V3_BATT: Voltage Sensor 26 UNC

  • BMC命令行界面system sensorsevents all命令或相应的SP-latest-IPMI和SP-latest-syslog AutoSupport 部分也会指示问题描述 :

BMC> system sensors filter BAT

Sensor Name    | Current   | Unit     | Status    | LCR     | LNC     | UNC     | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
P3V_BATT      | 2.840    | Volts    | nc     | 2.720    | 2.880    | 3.300    | 3.460

BMC> events all

Record 904: Wed Mar 18 02:14:02.350000 2020 [IPMI.notice]: 0001 | 02 | EVT: 0157bdbd | P3V3_BATT | Assertion Event, "Upper Non-critical going high" | Reading: 3.307 | Threshold: 3.307
 

Record 1946: Sun May 29 23:44:14 2022 [IPMI.notice]: 6501 | 02 | EVT: 0150bdbd | Bat_3.0V | Assertion Event, "Lower Non-critical going low"

 

控制器警示LED
  • 控制器上的琥珀色警告警示LED将亮起

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.