适用场景

  • FAS8200

问题描述

  • CHASSIS FAN FRU FAILED中有多条消息 EMS示例: 

[node-02: env_mgr: monitor.fru.info.unreadable:error]: The inventory information of FRU Fan2 is not readable.
[node-02: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan2 F1 (failed)
[node-02: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan2 F2 (failed)
[node-02: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F1
[node-02: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F2

  • 中的传感器错误 SP-LATEST-SYSLOG示例

Oct  5 02:33:39 (none) : [402 WARNING][hal_api.c:356]Sensor 55 reading error
Oct  5 02:33:39 (none) : [402 WARNING][hal_api.c:356]Sensor 56 reading error
Oct  5 02:33:45 (none) env_mgr[1165]: Failed to read fru cb  

  • 中的系统风扇和FRU相关消息 SP-LATEST-SYSTEM-EVENT-LOG

Record 774: Wed Jul 20 12:33:50 2022 [IPMI.notice]: 6401 | 02 | EVT: 6f01ffff | Sysfan2_Present | Assertion Event, "Absent"
Record 775: Wed Jul 20 12:33:51 2022 [IPMI.notice]: 6501 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
Record 776: Wed Jul 20 12:34:05 2022 [IPMI.warning]: FRUID 4 Access error
Record 777: Wed Jul 20 12:34:05 2022 [IPMI.notice]: 6601 | 02 | EVT: 6f00ffff | Sysfan2_Present | Assertion Event, "Present"

  • 在中未检测到设备 SYSCONFIG-M

!FAN1!021728019240!441-00025!A1!
!FAN2: Error reading FRU EEPROM
!FAN3!021728018994!441-00025!A1!

 