跳转到主内容

“ System Health Alert Show ”报告节点中的服务处理器没有网络连接

Views:
56
Visibility:
Public
Votes:
2
Category:
fas-systems<a>SP</a>
Specialty:
hw
Last Updated:

状态信息

适用场景

  • ONTAP 9
  • 服务处理器 (SP)

问题描述

系统出现有关 SP 中无网络连接的错误 system health alert show

示例:

cluster1::> system health alert show
               Node: node1
           Resource: SP Config
           Severity: Major
    Indication Time: Tue Aug 27 23:50:13 2019
           Suppress: false
        Acknowledge: false
     Probable Cause: Service Processor in node node1 has no network
                    connectivity.The cable between the Wrench port on the
                     controller and the ethernet switch is disconnected.
    Possible Effect: You might not be able to use the Service Processor to
                     remotely access, monitor, and troubleshoot your
                     storage system.
Corrective Actions: 1. Check the connection between the Wrench port and the ethernet switch.
                     2. If the cable is properly connected, ensure that the Service Processor's ethernet interface is configured properly by executing the command "system service-processor network show".
                     3. Check for network cable related issues.
                     4. Contact the technical support if the alert persists.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.