跳转到主内容

系统运行状况报告环境已降级、但无硬件故障

Views:
30
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2008892362</a><a>进行翻译</a>
Last Updated:

适用场景

ONTAP 9

问题描述

  • system health subsystem show 报告环境已降级。

ClusterA::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       degraded
Memory            ok
Service-Processor ok
Switch-Health     ok
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster
                  ok
13 entries were displayed.

  • system health alert show 报告PSU故障。

ClusterA::> system health alert show
               Node: NodeA-02
           Resource: PSU1#xxxxxxx
           Severity: Critical
    Indication Time: Mon Jul 05 07:30:07 2021
           Suppress: false
        Acknowledge: false
     Probable Cause: PSU1 is not present in the chassis xxxxxxx. The
                     nodes in this chassis are NodeA-02.
    Possible Effect: The nodes in the chassis might not function
                     effectively or redundancy might be lost.
 Corrective Actions: 1. Plug in PSU1 correctly into the slot.
                     2. Refer to the Hardware specification guide for more information on the position of the field-replaceable unit (FRU) and ways to check or replace it.
                     3. Contact support personnel if the alert persists.

  • 基于AutoSupport 、PSU不会出现故障。

PSU2 Bad                                 FALSE
PSU1 Bad                                 FALSE
PSU2 need replacement                       NO
PSU1 need replacement                       NO
PSU2                                      GOOD
PSU1                                      GOOD
Sysfan3 F2                                GOOD
Sysfan3 F1                                GOOD
Sysfan2 F2                                GOOD
Sysfan2 F1                                GOOD
Sysfan1 F2                                GOOD
Sysfan1 F1                                GOOD

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.