状态信息

适用场景

  • IOM 磁盘架模块
  • Data ONTAP 所有版本

问题描述

重新拔插或更换 IOM 模块后,您可能会发现以下异常:

 

  • sysconfig -a 显示磁盘架序列号,而不是磁盘正面的磁盘架 ID :

        SHM09797XXXXX.0: NETAPP X411_HVIPC420A15 NA02 418.0GB 520B/sect (CWYXXX)
     
  • sasadmin expander_map 可能显示无效 / 备用磁盘架 ID :

        Level 10: WWN 50050cc104fd6d3f, ID 150, Serial Number ' SHM09797XXXXX', Product 'DS424IOM3 ', Rev '0172', Slot B
 

  • 您可能会在消息日志中收到重复的磁盘架 ID 错误:

        [sas.shelf.conflict:error]: At least two SAS disk shelves have the same disk shelf ID.

 

 