"sysconfig-a " 将 "failed" 显示为 Flash Cache 状态
适用于
- FAS3220
- Data ONTAP 8.
问题
- ""
sysconfig -a
将 "" 显示Failed
为 Flash Cache 状态。
示例:
slot 2: Flash Cache 2 (512 GB)
State: Failed
Model Name: X1973A-R6
Serial Number: 9458198419
Part Number: 111-00902
Board Revision: D0
- EMS 日志报告“
iomem.card.fail.internal:critical
”和“fmm.domain.card.failure:error
”。
示例:
[?] Sun Feb 23 20:46:52 JST [node_name: iomem.card.fail.internal:critical]: Caching module (model name X1973A-R6, serial number 9458198419, part number 111-00902) in slot 2 has experienced a fatal internal error (0x4007) and is being taken offline.
[?] Sun Feb 23 20:46:52 JST [node_name: fmm_main: fmm.domain.card.failure:error]: Flash Cache in slot 2 (model name X1973A-R6, serial number 9458198419, part number 111-00902): Flash device failed and needs to be updated or repaired or replaced.