In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

对于 DS460C 抽屉中的磁盘, "PHY 报告链路速率未知 "

Views:
4
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用场景

  • DS460C
  • 已绕过磁盘

问题描述

  • 一个 IOM 绕过磁盘:

Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS460-12
Product Serial Number: SH0123456789
Module Type: IOM12
  ...
  11 [Bay  1]: CRITICAL      02,01,00,04   BYPASSED B
  ...

  • 混合路径配置: 

NetApp Release 9.8P6: Tue Aug 3 12:23:18 CET 2021
 System ID: 0123456789 (node_name-01); partner ID: 0123456780(node_name-02)
 System Serial Number: 012345678910(node_name-01)
 System Rev: D0
 System Storage Configuration: Mixed-Path HA

  • EMS 警报和错误: 

Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf 1, module B, drawer 1, PHY 1 is reporting an unknown link rate.
Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • 重新安装和更换磁盘后,问题描述仍会保留:

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support