DS460C抽屉中的磁盘" PHY报告未知链路速率"
适用场景
- DS460C
- 已绕过磁盘
问题描述
- 一个 IOM 绕过磁盘:
Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS460-12
Product Serial Number: SH0123456789
Module Type: IOM12
...
11 [Bay 1]: CRITICAL 02,01,00,04 BYPASSED B
...
- 混合路径配置:
NetApp Release 9.8P6: Tue Aug 3 12:23:18 CET 2021
System ID: 0123456789 (node_name-01); partner ID: 0123456780(node_name-02)
System Serial Number: 012345678910(node_name-01)
System Rev: D0
System Storage Configuration: Mixed-Path HA
- EMS 警报和错误:
Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf 1, module B, drawer 1, PHY 1 is reporting an unknown link rate.
Tue Oct 05 16:06:23 +0300 [node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- IOM模块不可用
Vendor Unique Element 83-IOM12B: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12B A] : OK 01,08,00,A0 MASTER, RESERVED, RESERVED
2 [IOM12B B] : NOT AVAILABLE 07,00,00,00
- 重新安装和更换磁盘后,问题描述仍会保留: