跳转到主内容

错误地报告 E 系列电源故障严重

Views:
10
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
hw
Last Updated:

适用场景

  • SG5712
  • 电源固件 01.10

问题描述

  • 在这种情况下 STORAGE-ARRAY-PROFILE ,电源 1 出现故障的原因是 - SHELVES

Power Supplies Detected:  2

Power supply status: Failed
Location:             Left
Part number:          114-00148+F1
Serial number:        Serial number
Date of manufacture:  Not Available

  • STATE-CAPTURE-DATA — evfShowVolssmShowSubTree —显示 PSU 1 状态正常:

[Power Supply]
Status:                Okay
Access Path Status:     Okay
Swapped?:               No
Predicted Fail?:        No
...
Slot:                  1
Parent Slot:            1
Relative Slot:          1
Relative Parent Locations: Enclosure(1) Support CRU(1)
...
Component Reported:     Yes
Error Rep When Missing: Yes
Attn Request / Attn On: No / No
...
Fault LED On?:         No
Additional Failure?:   No
Requested On?:         Yes
Off?:                  No
Has Power Input?:      Yes
DC Under Voltage?:     No
DC Failed?:            No
...
Firmware Revision:      01.10

  • 之后,错误消息消失, STORAGE-ARRAY-PROFILE 并将电源状态显示回 Optimal

Power Supplies Detected:  2

Power supply status: Optimal
Location:             Left
Part number:          114-00148+F1
Serial number:        Serial number
Date of manufacture:  Not Available

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.