跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

由于备用控制器中的设备无效、 E 系列控制器处于锁定状态( 0E L 0 或 06 L 0 )

Views:
42
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

适用于

  • 所有 E 系列硬件平台

问题

控制器锁定时,控制器背面的 7 段 LED 代码为 OEE L0 或 06 L0 。

这些代码指示由于硬件不匹配而锁定控制器。

-> spriSevenSegShow
Code: 0E L0
Condition: This controller is paired with an invalid device in its alternate controller slot. Replace the in correct controller canister device with a matching
value = 162 = 0xa2


以下错误消息可能会显示在引导顺序(控制台输出)和调试队列日志中:


CtrlMismatchErrType: Ctlr board id:0x15, Alt ctlr board id:0x10
CtrlMismatchErrType: MISMATCH - Controller Board ID=0x15, AltID=0x10

 

 

 

 

 