跳转到主内容

E系列控制器处于锁定状态(0E L0或06 L0)、因为备用控制器中的设备无效

Views:
45
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg<a>1006198</a><a>E系列控制器</a><a>锁定</a>
Last Updated:

适用场景

NetApp E 系列

问题描述

控制器在 OE L006 L0 控制器背面锁定、并显示一个或的7段LED代码。

这些代码表示控制器因硬件不匹配而被锁定。

-> spriSevenSegShow
Code: 0E L0
Condition: This controller is paired with an invalid device in its alternate controller slot. Replace the in correct controller canister device with a matching
value = 162 = 0xa2


启动序列(控制台输出)和调试队列日志中可能会显示以下错误消息:


CtrlMismatchErrType: Ctlr board id:0x15, Alt ctlr board id:0x10
CtrlMismatchErrType: MISMATCH - Controller Board ID=0x15, AltID=0x10

 

 

 

 

 