跳转到主内容

ONTAP Select :由于 SANtricity 操作系统已过时,已记录 vnvram.dma.long.wait

Views:
17
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
cloud
Last Updated:

适用场景

  • NetApp ONTAP Select
  • VMware
  • NetApp E 系列
  • NetApp SANtricity 11.70R3 (或更早版本)

问题描述

---- EMS_LOG ----
wafl_exempt00: vnvram.dma.long.wait:alert]: vNVRAM flush taking over 10 second

  • VMware 日志指示后端存储或 iSCSI 传输问题描述:

---- vmkwarning.log ----2021-05-10T18:16:27.205Z cpu11:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-13T06:23:24.252Z cpu1:2097807)WARNING: iscsi_vmk: iscsivmk_StopConnection:699: vmhba64:CH:1 T:0 CN:0: iSCSI connection is being marked "OFFLINE" (Event:6)2021-05-13T06:23:24.252Z cpu1:2097807)WARNING: iscsi_vmk: iscsivmk_StopConnection:700: Sess [ISID: 00023d000003 TARGET: iqn.1992-08.com.netapp:2804.600a098000db10c2000000005b0e507e TPGT: 1 TSIH: 0]2021-05-13T06:23:24.252Z cpu1:2097807)WARNING: iscsi_vmk: iscsivmk_StopConnection:701: Conn [CID: 0 L: xxx.xxx.xx.x:34428 R: 192.168.34.7:3260]2021-05-13T06:23:27.274Z cpu11:2098245)WARNING: iscsi_vmk: iscsivmk_StartConnection:880: vmhba64:CH:1 T:0 CN:0: iSCSI connection is being marked "ONLINE"2021-05-13T06:23:27.274Z cpu11:2098245)WARNING: iscsi_vmk: iscsivmk_StartConnection:881: Sess [ISID: 00023d000003 TARGET: iqn.1992-08.com.netapp:2804.600a098000db10c2000000005b0e507e TPGT: 1 TSIH: 0]2021-05-13T06:23:27.274Z cpu11:2098245)WARNING: iscsi_vmk: iscsivmk_StartConnection:882: Conn [CID: 0 L: xxx.xxx.xx.x:10121 R: 192.168.34.7:3260]2021-05-16T18:15:33.335Z cpu11:2101876)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-16T18:15:33.336Z cpu0:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-26T19:59:23.954Z cpu6:2101877)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-26T19:59:23.955Z cpu12:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-27T00:29:25.272Z cpu12:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-27T00:29:25.273Z cpu0:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-28T14:00:34.010Z cpu1:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-28T14:00:34.011Z cpu10:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-30T02:05:40.894Z cpu33:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-30T02:05:40.895Z cpu11:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-05-31T07:15:33.656Z cpu38:2101876)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-05-31T07:15:33.657Z cpu3:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-06-08T17:30:32.816Z cpu33:2101875)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-06-08T17:30:32.816Z cpu16:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-06-10T10:16:11.546Z cpu7:2101877)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-06-10T10:16:11.546Z cpu3:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...2021-06-14T18:16:36.032Z cpu32:2101877)WARNING: VSCSI: 3577: handle 8219(vscsi10:0):WaitForCIF: Issuing reset; number of CIF:12021-06-14T18:16:36.033Z cpu18:2097597)WARNING: NMP: nmp_DeviceRequestFastDeviceProbe:237: NMP device "naa.600a098000db1194000001e75c8f22b9" state in doubt; requested fast path state update...

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support