问题

如果在新设置中升级到集群模式 Data ONTAP 8.3 失败、并出现以下错误:


********************************************************************************
* This filer contains FreeBSD configured ports.
* You must correct this failure to avoid service disruptions.
*
* The following corrective action is required:
* Set the -privilege level do diagnostic:
* set -privilege diagnostic
* Issue the following commands:
* systemshell -node <node> 'kenv -upq bootarg.activatebsdport'
* systemshell -node <node> 'kenv -upq bootarg.activatebsdport.persist'
* systemshell -node <node> 'kenv -upq bootarg.givebsdmgmtport'
*******************************
*************************************************
Retry the image installation after taking corrective action.
ERROR: LIF sufficiency check failed.
Install Failed.
Install Validation Failed. ERROR: LIF sufficiency check failed.
Error: command failed: Install Failed. Install Validation Failed. ERROR: LIF sufficiency check failed.

 

 