适用场景

  • ONTAP 9
  • MetroCluster FC
  • Brocade 后端交换机

问题描述

  • 客户端报告延迟较长

  • scsi.cmd 事件日志中报告的错误:

示例:

[NodeA: isp2400_intrd: scsi.cmd.abortedByHost:error]: Disk device ATTO:8.126L1504: Command aborted by host adapter: HA status 0x4: cdb 0x9a:0000000121806060:0001:01a0.

Fri Apr 16 10:01:02 +0200 [sminfsa01001p: isp2400_intrd: mlm.excessive.TPlatency:notice]: Average latency of 258239us on target port 2100001086ad1f00, has exceeded 250000us

  • 低 SFP TX 启动交换机端口:

Switch:admin> sfpshow 8

RX Power: -1.5 dBm (708.8uW)
TX Power: -5.6 dBm (273.8 uW)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.