跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

在 Element 软件升级过程中、哪些 API 调用不起作用?

Views:
15
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用于

NetApp Element 软件

解答

此列表包含在 Element 软件升级期间无法执行的所有 API 调用。 

请注意,下面的 API 和 * 是允许forceDuringUpgrade NetApp 支持覆盖的 API 。在升级过程中,所有其他项都将被禁用。

警告:当集群处于“升级模式”时运行 API 时,应格外小心。如果在升级过程中运行这些 API 中的任何一个、请联系 NetApp 技术支持并参考本文以获得进一步帮助。
  • AddNodes*
  • RemoveNodes*
  • AddDrives*
  • RemoveDrives*
  • CreateInitiators*
  • DeleteInitiators*
  • ModifyInitiators*
  • CreateVolumeAccessGroup*
  • ModifyVolumeAccessGroup*
  • ModifyVolumeAccessGroupLunAssignments*
  • AddInitiatorsToVolumeAccessGroup*
  • RemoveInitiatorsFromVolumeAccessGroup*
  • AddVolumesToVolumeAccessGroup*
  • RemoveVolumesFromVolumeAccessGroup*
  • DeleteVolumeAccessGroup*
  • SecureEraseDrives
  • EnableEncryptionAtRest
  • DisableEncryptionAtRest
  • AddVirtualNetwork
  • RemoveVirtualNetwork
  • ModifyVirtualNetwork
  • EnableFeature
  • SetSSLCertificate
  • RemoveSSLCertificate
  • SetClusterStructure
  • CheckProposedNodeAdditions
  • SetSupplementalTlsCiphers
  • ResetSupplementalTlsCiphers

* 可以使用forceDuringUpgrade选项执行的 API 。

注:

  • 从 Element Software 11.7 和更高版本开始、升级期间仅适用于 iSCSI 的集群将取消 API 限制
  • API 限制将继续适用于包含光纤通道 (FC) 节点的任何集群、而不考虑 Element 软件版本

其他信息

附加信息 _text

 

Scan to view the article on your device