In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

有关 SolidFire Element OS 升级的常见问题

Views:
10
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用于

NetApp Element 软件 10.3 及更高版本

解答

  1. 由于集群中存在已知问题而出现以下错误,这些错误是否会影响或运行状况检查? sfinall
示例:
Error Code      Details
nodeHardwareFault  Chassis component "Memory" reports status as "Critical".
nodeHardwareFault  NVRAM device warning={fanInletAmbientTemperature: 56.67 C}
 
  • 这些检查 nodeHardwareFault 不会在运行状况检查中报告,因为它会检查集群中的集群故障。
  • 它也不会影响 sfinstall 升级命令。
  • 此外,如果 -f sfinstall 需要,在命令中使用选项可以绕过可忽略的集群故障。

 

  1. 升级最后一个节点(集群主节点)时,是否会关闭通过 MVIP 的连接?
  • 在升级期间,集群主角色将降级到另一个节点,因此,此节点上的连接也会重定向到新的集群主节点。

 

  1. 在节点升级期间,如果其他节点上发生 SSD 故障或节点故障,集群容量会发生什么变化?
  • 在通过 upgrade 命令设置的 BS kill 计时器(默认值为 1 小时 15 分钟)期间,此状态不会发生任何更改。

 

  1. 对于升级期间发生的任何节点或 SSD 故障,如果故障部件将双 Helix 数据保存在升级节点上,是否只能在节点升级后执行恢复操作?

 

  1. 对于上述情景 4 ,对客户有何影响?
  • 在大多数情况下,写入操作几乎不会产生任何影响,但对于需要访问故障部件的读取操作,写入操作会受到影响。 
     