交换机维护 / 故障后,远程驱动器出现故障
适用于
- ONTAP 9
- MetroCluster IP
- A300/FAS8200 , A200/FAS2600 , A220/FAS2700 或 C190
问题
在后端交换机维护或出现故障后, sysconfig -a
将显示类似于以下内容的输出:
slot 0: Virtual iSCSI Host Adapter 0m
...
10.20: NETAPP X371_SLNGE960ATE NA52 915.4GB 520B/sect (S/N) (Failed)
sysconfig -r
输出如下所示:
Local broken disks RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- not responding 0m.i2.1L21P3 0m 0 21 1 SSD N/A 63849/130764288 63857/130780672 ... not responding 0m.i1.3L27 0m 10 20 1 SSD N/A 915465/1874872832 915715/1875385008 Disaster recovery partner broken disks RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- partner 0m.i1.6L33 0m 10 9 0 SSD N/A 915465/1874872832 915715/1875385008