跳转到主内容

如何修改多个卷的-in-nvfailed-state?

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用场景

  • ONTAP 9
  • 卷处于 nvfailed状态

问题解答

volume命令将的所有卷更-in-nvfailed-state true 改为 -in-nvfailed-state false

::> volume modify {-vserver <SCM_name> -volume * -in-nvfailed-state true} -in-nvfailed-state false

追加信息

要列出卷及其 nvfail状态、请使用: volume show -fields nvfail
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.