为什么在发生多个磁盘故障后聚合会脱机
适用场景
- ONTAP 9
- AFF
- FAS
问题解答
- RAID4 中的 2 个或更多
- RAID-DP 中为 3 个或更多
- RAID-TEC 中的 4 个或更多
RAID-DP 示例:
Cluster::> run -node Node-01 sysconfig -r
- 之前:
RAID group Aggr1/plex0/rg1 (normal, block checksums)
 
 RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
 ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
 dparity     0a.12.16    0a    12  16  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 parity      0a.12.17    0a    12  17  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 ...
 data        0a.11.6     0a    11  6   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.7     0a    11  7   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.8     0a    11  8   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.9     0a    11  9   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.10    0a    11  10  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.19    0a    11  19  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.12    0a    11  12  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.13    0a    11  13  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.14    0a    11  14  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.15    0a    11  15  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 ...- 两个磁盘出现故障:
RAID group Aggr1/plex0/rg1 (double degraded, block checksums)
 
 RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
 ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
 dparity     0a.12.16    0a    12  16  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 parity      0a.12.17    0a    12  17  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 ...
 data        0a.11.6     0a    11  6   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data   FAILED          N/A                        857000/ -
 data        0a.11.8     0a    11  8   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.9     0a    11  9   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.10    0a    11  10  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.19    0a    11  19  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.12    0a    11  12  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.13    0a    11  13  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data   FAILED          N/A                        857000/ -
 data        0a.11.15    0a    11  15  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 ...- 两个以上磁盘故障:
Aggregate Aggr1 (failed, raid_dp, partial) (block checksums)
   Plex /Aggr1/plex0 (offline, failed, inactive)
     RAID group /Aggr1/plex0/rg1 (normal, block checksums)
RAID Disk    Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
 ---------    ------      ------------- ---- ---- ---- ----- --------------    --------------
 dparity     0a.12.16    0a    12  16  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 parity      0a.12.17    0a    12  17  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 ...
 data        0a.11.6     0a    11  6   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data    FAILED          N/A                        857000/ -
 data        0a.11.11    0a    11  11  SA:B   0   SAS 15000 857000/1755136000 858483/1758174768 (reconstruct stalled)
 data        0a.11.9     0a    11  9   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.10    0a    11  10  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data    FAILED          N/A                        857000/ -
 data        0a.11.12    0a    11  12  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data        0a.11.13    0a    11  13  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 data    FAILED          N/A                        857000/ -
 data        0a.11.15    0a    11  15  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
 ...
 Raid group is missing 3 disks.