跳转到主内容

为什么在固件升级期间 SP/BMC 重新启动?

Views:
24
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • 所有平台
    • ASA系统
    • AFF 系统
    • FAS 系统

问题解答

SP/BMC 更新完成后、SP/BMC将自动重新启动。 

  • ONTAP将在重新启动SP/BMC之前通知您。

Firmware update will need to reboot the SP on completion. If your console connection is through the SP, it will be disconnected.

  • 要显示SP/BMC更新状态、包括是否正在进行更新、更新开始和结束时间以及完成百分比、请执行以下操作:
system service-processor image update-progress show -node node_name
 
Node: node_name
Latest SP Firmware Update Start Timestamp: 7/18/2017 12:22:37
Latest SP Firmware Update Percentage Done: 100
Latest SP Firmware Update End Timestamp: 7/18/2017 12:28:14
Is Update in Progress: no
  • 要验证SP/BMC是否已联机并运行预期版本、请运行:

system service-processor show -node node_name

追加信息

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.