跳转到主内容

bootarg.watch.max_concurrent_posts 的默认值和最大值是多少?

Views:
2
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用场景

ONTAP 9

问题解答

在 ONTAP 9.2 及更高版本中,这些值会发生更改。
  • 监视柱插槽的默认数量从 8 个增加到 163 个。
  • bootarg.watch.max_concurrent_posts bootarg 的最大值从 96 增加到 2048 。

追加信息

如果 bootarg.watch.max_concurrent_posts 的值设置得过低,则某些应用程序可能会失败。

使用以下命令更改此值以满足应用程序的要求。

node run -node * bootargs set bootarg.watch.max_concurrent_posts < new value >

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.