跳转到主内容

系统报告使用IOM6和IOM12模块的多路径布线配置下的单路径

Views:
40
Visibility:
Public
Votes:
0
Category:
fas-systems<a>multipath</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • FAS / ASA / AFF平台
  • 支持IOM6/IOM12 堆栈混合 

问题描述

  • 为多路径布线时,系统报告单路径。
  • IOM6 和 IOM12 在同一个堆栈中混合使用。 
    • 验证兼容性: HWU 。转至 "Storage Limits" (存储限制)>"Full Storage Limit Matrix"(完整存储限制表) >"SupportedsShelts/Driv
  • 如果布线不正确,系统可能会触发类似于以下内容的 EMS 消息:

[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = IOM12ToIOM6SquarePortConnection_Alert , Alerting Resource = 1234567..... raised by monitor node-connect
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = MixOfIOMAandIOMBConnection_Alert , Alerting Resource = 1234567.....:2 raised by monitor node-connect
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = SinglePathToDiskShelf_Alert , Alerting Resource = 1234567..... raised by monitor node-connect

 

  • IOM6 方形端口所连接的端口将被禁用:

Shelf name:   Partner.shelf0
Shelf id:    0
Channel:     Partner
Module:     A
        Partial Path   Link   Invalid   Running    Loss   Phy     CRC    Phy
Disk   Port   Timeout     Rate    DWord   Disparity   Dword   Reset    Error   Change
Id    State   Value (ms)   (Gb/s)   Count   Count     Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[SQR0] NO SIGNAL   7      NA     0       0     0     0      0     6
[SQR1] NO SIGNAL   7      NA     0       0     0     0      0     6
[SQR2] NO SIGNAL   7      NA     0       0     0     0      0     6
[SQR3] NO SIGNAL   7      NA     0       0     0     0      0     6

Shelf name:   0b.shelf1
Shelf id:    1
Channel:     0b
Module:     A
        Partial Path   Link   Invalid   Running    Loss   Phy     CRC    Phy
Disk   Port   Timeout     Rate    DWord   Disparity   Dword   Reset    Error   Change
Id    State   Value (ms)   (Gb/s)   Count   Count     Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[HST8] DIS/ILLGL   7      NA     0       0     0     1      0     4
[HST9] DIS/ILLGL   7      NA     0       0     0     0      0     4
[HST10] DIS/ILLGL   7      NA     0       0     0     1      0     4
[HST11] DIS/ILLGL   7      NA     0       0     0     1      0     4

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.