跳转到主内容

站点电源问题会导致DS4246上的多个磁盘出现故障

Views:
8
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009150768</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS/AFF 系统
  • 安装了2个(共4个) PSU的DS4246

问题描述

  • DS4246磁盘架上安装了4个PSU中的2个
  • 电源维护会导致一个或两个PSU发生波动和不稳定
  • 受影响磁盘架上的磁盘无响应失败、并且可以看到有关磁盘旋转的错误

Wed Apr 27 06:44:25 EDT [node01: label_thread: raid.label.io.writeError:notice]: Label write on Disk /aggr1/plex0/rg0/0a.03.10 Shelf 3 Bay 10 [NETAPP X306_HMARK02TSSM NA04] S/N [YFHRLMNA] UID [500605BA:008FD048:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] failed with storage error no valid path to disk. The system will stop using the disk for I/O operations.

Wed Apr 27 06:45:02 EDT [node01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1/plex0/rg0/0a.03.10 Shelf 3 Bay 10 [NETAPP X306_HMARK02TSSM NA04] S/N [ABCDEFGH] UID [12345AAA:000BB000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.

Wed Apr 27 08:47:36 EDT [node01: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 0a.03.10: Device returns not yet ready: CDB 0x28:703c78f8:0009: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x28)(60869).
Wed Apr 27 08:47:36 EDT [node01: scsi_cmdblk_strthr_admin: disk.timeout.flush.start:debug]: Aggressive timeout flush started on disk 0a.03.10.
Wed Apr 27 08:47:36 EDT [node01: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 0a.03.10: Device returns not yet ready: CDB 0x28:52e2ccd3:0009: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x28)(60870).
Wed Apr 27 08:47:36 EDT [node01: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 0a.03.10: Device returns not yet ready: CDB 0x28:52e2c997:0009: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x28)(60871).
Wed Apr 27 08:47:36 EDT [node01: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 0a.03.10: Device returns not yet ready: CDB 0x28:9a02d9e9:0009: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x28)(60871).

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.