跳转到主内容

具有SP磁盘架故障RQSTd状态的磁盘架模块会生成每小时警告

Views:
6
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009062788</a><a>进行翻译</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS26x0
  • AFF A200
  • 服务处理器(SP)固件5.10
  • ONTAP 9
  • IOM12E磁盘架模块

问题描述

  • 两个ACP处理器均报告错误: 

[node_name-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'ENCLOSURE DATA BUSY (WWN 5:00a098:003c92b:3f) -- retry 1', 'adapterName': '0a'}
[node_name-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'ENCLOSURE DATA BUSY (WWN 5:00a098:003c92b:3f) -- retry 2', 'adapterName': '0a'}
[node_name-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'REPORT ID INFO failed (WWN 5:00a098:003c92b:3f): function_result 0x5 -- will need to synthesize value.', 'adapterName': '0a'}

[node_name-01: dsa_worker2: ses.status.acperror:ALERT]: DS212-12 (S/N SHABC1234567890) shelf 0 on channel 0b ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
[node_name-01: dsa_worker2: ses.status.acperror:ALERT]: DS212-12 (S/N SHABC1234567890) shelf 0 on channel 0b ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
[node_name-02: dsa_worker1: ses.status.acperror:ALERT]: DS212-12 (S/N SHABC1234567890) shelf 0 on channel 0a ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
[node_name-02: dsa_worker1: ses.status.acperror:ALERT]: DS212-12 (S/N SHABC1234567890) shelf 0 on channel 0a ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.

[node_name-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[node_name-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • STORAGE-FAULT 输出中所示的顺序相同。

::> system node run -node <node_name> -command storage show fault
Enclosure Status: critical
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: XXXXXXXXXXXXXXX
Module Type: IOM12E
Enclosure:
Element Status      Status Bytes  Status Descriptions
  1: OK         01,00,02,00  FAIL
Vendor Unique Element 85-IOM12E: (ACP)
Element Status            Status Bytes  Status Descriptions
  1 [IOM12E A]   : CRITICAL     02,18,00,40   NO ACPP, INBACP, FAIL
  2 [IOM12E B]   : CRITICAL      02,18,00,40   NO ACPP, INBACP, FAIL
Vendor Unique Element 88-IOM12E: (PCM)
Element Status      Status Bytes  Status Descriptions
  1: OK         01,01,80,00  SP SHELF FAULT RQSTD
  2: OK         01,01,80,00   SP SHELF FAULT RQSTD

 

  • 服务处理器重新启动后、问题描述 仍会保持不变
  • 由于此问题描述、风扇噪音或转速值可能高于正常值

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.