问题描述

  • 系统采用混合路径
  • IOM安装不正确或出现故障
  • ::> node run -node * storage show fault -v
     
    [truncated]
    Enclosure Electronics:
    Element Status                      Status Bytes  Status Descriptions
      1 [IOM12 A]    : OK                01,00,01,00   REPORT
      2 NOT INSTALLED                  05,00,00,00  

    在Sysconfig中、未列出磁盘架模块的固件

    ::> node run -node * sysconfig -a
     Shelf 0: DS212-12 Firmware rev. IOM12E A: 0201 IOM12E B: 0201 Shelf 1: DS212-12 Firmware rev. IOM12 A: 0250 IOM12 B: 0250 Shelf 2: DS212-12 Firmware rev. IOM12 A: 0250 B: ---- 
  • 对于从控制器或其他磁盘架连接到IOM的SAS缆线、链路LED均不亮

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 