传感器LED1或LED2非严重阈值上限导致环境关闭
适用场景
- AFF A400
- AFF A800
- ONTAP 9
问题描述
- 温度传感器LED1和LED2会在°达到非严重阈值上限(43 C)时触发环境关闭、而不是通常触发环境关闭的严重阈值上限:
Sun Jan 08 00:45:57 +0000 [Node1: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Ambient temperature is warning high. System will be shutdown in 2 minutes Sun Jan 08 00:45:57 +0000 [Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: LED2 Temp is warning high (43 C). Sun Jan 08 00:46:00 +0000 [Node1: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high.. Sun Jan 08 00:46:56 +0000 [Node1: env_mgr: callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN Sun Jan 08 00:46:56 +0000 [Node1: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE