跳转到主内容

SECD进程进入循环、因为SMDB表"cifs_lug_domain_object_sid_cache_db"包含非法重复条目并带有"-"

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas<a>2009268590</a>
Last Updated:

适用场景

ONTAP 9

问题描述

CIFS访问会受到影响、因为SECD进程会进入环路状态。

  • Secd日志显示:

Thu Aug 25 2022 02:47:15 +09:00 [kern_secd:info:12851] | [000.138.250]  ERR  : While populating source name 'DomainSidCache' DSMF next failed with error Loop
detected in next() for table cifs_lug_domain_object_sid_cache_db. Next on "xxx 1-119" returned "xxxx 1-119"..  { in populateStore() at src/include/secd_configuration_sources.h:522 }
 
Thu Aug 25 2022 02:47:15 +09:00 [kern_secd:info:12851] | [000.135.269]  ERR  : While syncing source name 'DomainSidCache' DSMF next failed with error Loop
detected in next() for table cifs_lug_domain_object_sid_cache_db. Next on "xxx 1-119" returned "xxxx 1-119"..  { in syncStore() at src/include/secd_configuration_sources.h:690 }

  • MGWD日志显示:

00000015.0029b548 4bf3604b Mon Aug 22 2022 12:48:14 +09:00 [kern_mgwd:info:80872] Error: Loop detected in next() for table cifs_lug_domain_object_sid_cache_db. Next on "xxxx 4-514" returned "- -".
00000015.0029b549 4bf3604b Mon Aug 22 2022 12:48:14 +09:00 [kern_mgwd:info:80872] Error: Loop detected in next() for table cifs_lug_domain_object_sid_cache_db. Next on "xxxx 4-1888" returned "- -".
00000015.0029b54a 4bf3604b Mon Aug 22 2022 12:48:14 +09:00 [kern_mgwd:info:80872] Error: Loop detected in next() for table cifs_lug_domain_object_sid_cache_db. Next on "xxxx 4-1999" returned "- -".

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.