SAS在单个磁盘上运行差异错误
适用场景
- ONTAP 9
- AF/FAS系统
- 驱动器 X357_KPM6V3T8ATE
问题描述
X 路径中的磁盘架在单个驱动器上显示无效的DWORD和差异错误。
[cluster1: dsa_worker5: ds.sas.running.disparity:debug]: [23 ] on channels 0a shelf ID 0 IOM B bay 23 reports running disparity errors.
[cluster1: dsa_worker3: ds.sas.running.disparity:debug]: [23 ] on channels 0a shelf ID 0 IOM B bay 23 reports running disparity errors.
Shelf name: 0a.shelf0
Shelf id: 0
Channel: 0a
Module: B
Shelf UID: 50:0a:09:80:0e:94:8c:96
Shelf S/N: SHJHU2214XXXX48
Term switch: N/A
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------------
[ 23 ] OK 7 12.0 10365 9891 0 0 0 1