跳转到主内容

SAS在单个磁盘上运行差异错误

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009870530</a>
Last Updated:

适用场景

  • ONTAP 9
  • AF/FAS系统
  • 驱动器 X357_KPM6V3T8ATE 

问题描述

X 路径中的磁盘架在单个驱动器上显示无效的DWORD和差异错误。
 
[cluster1: dsa_worker5: ds.sas.running.disparity:debug]: [23 ] on channels 0a shelf ID 0 IOM B bay 23 reports running disparity errors.
[cluster1: dsa_worker3: ds.sas.running.disparity:debug]: [23 ] on channels 0a shelf ID 0 IOM B bay 23 reports running disparity errors.
 
Shelf name:   0a.shelf0
Shelf id:    0
Channel:     0a
Module:     B
Shelf UID:    50:0a:09:80:0e:94:8c:96
Shelf S/N:    SHJHU2214XXXX48
Term switch:   N/A
Shelf state:   ONLINE
Module state:  OK
           Partial Path   Link   Invalid   Running    Loss   Phy     CRC    Phy
Disk      Port   Timeout     Rate    DWord   Disparity   Dword   Reset    Error   Change
Id       State   Value (ms)   (Gb/s)   Count   Count     Count   Problem   Count   Count
--------------------------------------------------------------------------------------------------
[ 23     ] OK        7     12.0   10365    9891     0     0      0     1

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.