EMS 报告 "shelf_fault" 并显示 "ses.status.ACPError : critical"
状态信息
适用场景
- I/O 模块( IOM )
- Alternate Control Path(备用控制路径)(ACP)
- 服务处理器 (SP)
问题描述
EMS 报告 "shelf_fault" 并显示 "ses.status.ACPError : critical" 。
示例:
Sat Mar 19 22:41:51 EST [xxx:ses.status.ACPError:CRITICAL]: DS4246 (S/N XXXXXXXXX) shelf 11 on channel 2c ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the bottom center, on shelf module B.
Sat Mar 19 22:41:54 EST [xxx:monitor.shelf.fault:CRITICAL]: Fault reported on disk storage shelf attached to channel 1b. Check fans, power supplies, disks, and temperature sensors.
Sat Mar 19 22:41:54 EST [xxx:callhome.shlf.fault:error]: Call home for SHELF_FAULT
ACP输出:
Cluster::> storage shelf acp module show -node node1
Node Module Name State
----------------- ----------------- ----------------------
node1 x.x.B active
x.x.A rebooting
Cluster::> node run -node node1 acpadmin ibacp_list_all
Number of ACP modules 2
MAC SES Last Contact Protocol Assigner Shelf Current Inband IOM shelf
Address bit (seconds ago) Version ACPA ID S/N State ID Type flag
---------------------------------------------------------------------------------------------------------------
00:a0:98:d5:29:c3 01 599374 1.2.02.12 0 xxxxx1809000006 0xd 0a.00.B IOM6 0x20
00:a0:98:d5:2e:73 01 123 1.2.02.12 0 xxxxx1809000006 0x17 0a.00.A IOM6 0x20