跳转到主内容

在 ONTAP 升级期间,节点停留在 "BIOS image updated , resetting to load defaults" 处

Views:
16
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS8200
  • 自动无中断升级( ANDU ),从 9.5P9 升级到 9.7P7

问题

  • 节点在更新期间会出现消息,并显示消息,但确实会出现此问题 请勿继续
 
BIOS image updated, resetting to load defaults
 
  • ONTAP 更新状态为已暂停
 
SP 事件日志显示节点发生 L2 watchdog 重置
 
[SysFW.notice]: Updating flash. Current BIOS version: 11.1
[SysFW.notice]: New BIOS version: 11.4
[IPMI.notice]: 3f01 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
[IPMI Event.critical]: L2 watchdog timeout power cycle
[IPMI.notice]: 4001 | 02 | EVT: 6fc302ff | System_Watchdog | Assertion Event, "Power cycle"
[IPMI Event.critical]: L2 watchdog action completed
[SP.notice]: Delaying L2_WDOG ASUP email for 120 seconds
[IPMI.notice]: 4101 | 02 | EVT: 6fc100ff | System_FW_Status | Assertion Event, "Unspecified"
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.