跳转到主内容

网络端口关闭、QSFP报告无接收器电源

Views:
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009年496725</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A700
  • X91440A适配器
  • ONTAP 9

问题描述

  • 网络端口已关闭

slot 8: 10/40 Gigabit Ethernet Controller XL710 QSFP+      
e8e MAC Address:    d0:39:ea:4b:67:72 (auto-unknown-fd-down)         
QSFP Vendor:                 
QSFP Part Number:            
QSFP Serial Number:        
Device Type:        XL710 B1      
Firmware Version:   fw 5.20 nvm 5.05 etid 80008d4d      
Part Number:        111-02590      
Hardware Revision:  B0      
Serial Number:      032139001292

  • AutoSupport 文件 ifconfig-vvvm 显示QSFP上无接收电源:

e8e: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 9000
lane 1: RX: 0.00 mW (-24.32 dBm) TX: 0.38 mW (-4.18 dBm)
lane 2: RX: 0.00 mW (-40.00 dBm) TX: 0.38 mW (-4.18 dBm)
lane 3: RX: 0.00 mW (-40.00 dBm) TX: 0.38 mW (-4.11 dBm)
lane 4: RX: 0.00 mW (-21.80 dBm) TX: 0.41 mW (-3.87 dBm)

  • 已对缆线进行了编码、以便在两端进行连接

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
Scan to view the article on your device

 

  • 这篇文章对您有帮助吗?