NVDIMM状态警报原因:固件错误、在配备NVDIMM的系统上
适用场景
- ONTAP 9
- AFF A800、AFF A400、AFF A320
- FAS8700、FAS8300
- NVDIMM
- 运行状况说明:NVDIMM固件错误
问题描述
EMS
Sun Jun 06 17:17:15 -0700 [NetApp1: nphmd: hm.alert.raised:alert]: Alert Id = NVDIMMBadHealthAlert , Alerting Resource = /dev/nvdimm0:NetApp1 raised by monitor controller
AutoSupport 部分: NVDIMM-status
Total NVDIMM on this platform is 1 -------------------------------------------------- DIMM(/dev/nvdimm0) Page:0 -------------------------------------------------- 0x0000: 00 0a 0a 01 01 00 21 3c 25 3c 25 34 34 00 00 00 0x0010: 1f 2e 00 00 03 15 03 0b 68 81 02 00 68 81 1e 80 0x0020: 05 80 78 80 05 00 00 40 1f ac 0d d0 07 a0 0f 90 0x0030: 33 08 08 dc 05 10 80 00 00 00 70 03 00 00 00 00 0x0040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0x0050: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ----------------------------------------------------- -------------------------------------------------- DIMM(/dev/nvdimm0): -------------------------------------------------- Controller Ready: Yes Controller Busy: No Energy Policy managed by: HOST Save_N Low During CSAVE: Yes Save_N Enabled(ARMED): Yes Data on the Flash: NotValid Module is Health: No Module Status(0x0040): NVDIMM FIRMWARE error Flash Lifetime: 86% Flash Lifetime Status: Normal
运行状况警报示例:
::>system health alert show
节点 | NetApp 1 |
---|---|
监控 | controller |
Alert ID | NVDIMMADHealthAlert |
警报资源 | /dev/nvdimm0:NetApp1 |
子系统 | 主板 |
指示时间 | Sun Jun 06 17:17:15 2021 |
感知的严重性 | 重大 |
可能的发生原因 | 硬件降性 |
问题描述 | 节点"NetApp1"上的NVDIMM"NVDIMM-N 0 (DIMM-11)"指示状态为已降级。 |
更正操作 | 请联系技术支持以获得有关更换NVDIMM模块的帮助。 |
可能的影响 | NVDIMM降级后可能会丢失数据。 |
确认 | false |
禁止 | false |
策略 | NVDIMMADHealthPolicy |
确认者 | |
禁止程序 | |
追加信息 |
节点:NetApp1 |