切换后的NVMe连接存储出现MismatchedHAPairtoPortRangeA_Alert错误
适用场景
- AFF 系统
- 交换式NVMe连接存储
问题描述
- 在中
SYSTEM-HEALTH-ALERT.XML
Node: node-1
Alert ID: MismatchedHAPairtoPortRangeA_Alert
Resource: Switch name: sw2(FLM23456A7)
Severity: Major
Indication Time: Mon Mar 10 11:04:07 2022
Suppress: false
Acknowledge: false
Probable Cause: Controller "node-1" and its HA partner are not
connected to switch "sw2(FLM23456A7)" with
the same port range.
Possible Effect: This configuration is not supported.
Corrective Actions: 1. Consult the guide "Setup and configuration guide for Cisco shared switches" to review the cabling rules for your system.
2. Connect controller "node-1" and its HA partner
to NVMe shelves with shared switches in the same port
range.
Node: node-2
Alert ID: SingleSwitchToShelf_Alert
Resource: Node node-2
Severity: Major
Indication Time: Mon Mar 10 10:41:59 2022
Suppress: false
Acknowledge: false
Probable Cause: Controller node-2 is connected to NVMe storage
shelves 1.1, 1.0 through only one switch sw1.
Possible Effect: You will lose access to shelves if switch sw1
fails.
Corrective Actions: 1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect controller node-2 to NVMe shelves
through two storage switches.
- 在
SYSCONFIG-A
的中node-2
System Storage Configuration: Mixed-Path HA
System ACP Connectivity: Inband Active
SAS2/SAS3 Mixed Stack Support: all
slot 2: Dual 40G/100G/200G Ethernet Controller CX6
e2a MAC Address: d0:39:ea:aa:99:bb (auto-100g_cr4-fd-up)
QSFP Vendor: Molex
QSFP Part Number: 112-00574
QSFP Serial Number: 93A2127890123
1.0.0: NETAPP X4014S173315TNTE NA53 14651.0GB 4160B/sect (S60SNE0T201234)
1.0.1: NETAPP X4014S173315TNTE NA53 14651.0GB 4160B/sect (S60SNE0T205678)
slot 10: Dual 40G/100G/200G Ethernet Controller CX6
e10a MAC Address: d0:39:ea:ee:77:a1 (auto-unknown-fd-down)
QSFP Vendor: Molex
QSFP Part Number: 112-00574
QSFP Serial Number: 93A2127123456