跳转到主内容

如果在计划的 SnapMirror 传输结束之前断开网络连接,是否可以触发通知?

Views:
14
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用于

ONTAP 9.x

解答

如果在计划 SnapMirror 传输结束之前断开网络连接,则 EMS 日志将输出以下消息。
 
[xxxx: sm_logger_main: smc.snapmir.schd.trans.overrun:error]: Scheduled transfer from source volume 'xxxx:xxxx' to destination volume 'xxxx' is taking longer than the schedule window. Relationship UUID 'xxxx'.
 
可以考虑通过筛选器事件 "smc.snapmir.schd.trans.zail" 设置电子邮件通知。
 
有关设置筛选器事件的详细信息,请参见如何为电子邮件目标配置事件筛选器和事件通知

其他信息

附加信息 _text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.