适用场景
- ACP处理器
- IOM12磁盘架
问题描述
- 关键外部磁盘架警报示例:
ALERT monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
::> storage shelf show
Module Operational
Shelf Name Shelf ID Serial Number Model Type Status
----------------- -------- --------------- ----------- ------ -----------
1.1 1 SHFHU1234567890 DS224-12 IOM12 Normal
2.11 11 SHFHU1234567891 DS224-12 IOM12 Normal
2.12 12 SHFHU1234567892 DS224-12 IOM12 Critical
3 entries were displayed.
- ACP错误示例:
::> storage shelf show -errors
Shelf Name: 2.12
Shelf UID: 50:0a:0b:0c:0d:0a:0b:0c
Serial Number: SHFHU1234567892
Error Type Description
------------------ ---------------------------
ACPP -
ACPP -
storage shelf fault
输出示例:
Enclosure Status: critical
Channel: 0b
Shelf: 12
Shelf Type: DS224-12
Product Serial Number: SHFHU1234567893
Module Type: IOM12
Vendor Unique Element 85-IOM12: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
2 [IOM12 B] : CRITICAL 02,18,00,40 NO ACPP, INBACP, FAIL
- 更新磁盘架固件后、问题描述仍会保留:
::> storage shelf show -fields module-fw-revision
shelf module-fw-revision
----- ------------------
1.1 0310,0310
2.11 0310,0310
2.12 0310,0310
3 entries were displayed.
- 禁用/启用ACP子系统后、问题描述仍会保留