问题

  • 控制器断电,由于"多个风扇发生故障"事件,导致合作伙伴接管。
  • AutoSupport 生成:HA Group Notification (MULTIPLE FAN FAILED: System will shut down in 2 minutes) ERROR
  • EMS / 事件日志将显示以下一个或多个风扇错误:

::> event log show -event *fan*

[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F1 at failed
[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F2 at failed
[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F3 at failed
[cluster-01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F4 at failed
[cluster-01: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[cluster-01: monitor: monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: FanB1 F1, FanB1 F2, FanB1 F3, FanB1 F4. 
[cluster-01: env_mgr: callhome.c.fan.fru.shut:error]: Call home for MULTIPLE FAN FAILED: System will shut down in 2 minutes
[cluster-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)

  • SP syslog(包含在 sp status -d 输出中)包含:

[477 WARNING][Porting/platform/PDKFan.c:1397]FanDaemon: Failure to read FanModuleData from fan module 1
[477 WARNING][Porting/platform/PDKFan.c:1416]FanDaemon: Fan module 1 marked bad after 3 consecutive failures
[477 WARNING][Porting/platform/PDKFan.c:1397]FanDaemon: Failure to read FanModuleData from fan module 1
[477 WARNING][Porting/platform/PDKFan.c:1416]FanDaemon: Fan module 1 marked bad after 3 consecutive failures

  • system node environment sensors show 的输出指示 FRU FanB1(或其他受影响的风扇)上的故障/MULTIFAULT。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.