由于FAS9000中的风扇故障、环境关闭
适用场景
- ONTAP 9
- AFF A700/FAS9000
- SP固件版本4.7或更高版本
问题描述
由于"Multiple fans has failed (多个风扇出现故障)" 事件、控制器已关闭、从而导致配对节点接管。
- 检查EMS/事件日志:
::> event log show -event *fan*
Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F1 at failed
Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F2 at failed
Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F3 at failed
Thu Mar 05 11:20:05 CET [node_name: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: FanB1 F4 at failed
Thu Mar 05 11:20:07 CET [node_name: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
Thu Mar 05 11:20:35 CET [node_name: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: FanB1 F1
Thu Mar 05 11:20:35 CET [node_name: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: FanB1 F2
- 检查SP日志输出:
Mar 2 08:15:24 (none) : [477 WARNING][Porting/platform/PDKFan.c:1397]FanDaemon: Failure to read FanModuleData from fan module 1
Mar 2 08:15:24 (none) : [477 WARNING][Porting/platform/PDKFan.c:1416]FanDaemon: Fan module 1 marked bad after 3 consecutive failures
Mar 2 08:15:30 (none) : [477 WARNING][Porting/platform/PDKFan.c:1397]FanDaemon: Failure to read FanModuleData from fan module 1
Mar 2 08:15:30 (none) : [477 WARNING][Porting/platform/PDKFan.c:1416]FanDaemon: Fan module 1 marked bad after 3 consecutive failures
- 检查以下各项的输出:
::> system node run -node <node_name> environment status chassis all