跳转到主内容

存储设备状态为“ Critical ”(严重)、错误为“ Power Control State : Critical ”(电源控制状态:严重)—检测到电源控制故障

Views:
52
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • DS14mk4 FC
  • Data ONTAP 8
  • SCSI 存储设备服务( SE )

问题

  • 机柜状态和电源控制在命令 "" 中是关键storage show fault的。

示例:

Enclosure Status: critical
Channel: 12b
Shelf: 1
Shelf Type: DS14-Mk4-FC
Product Serial Number: OPS67734221717E
Module Type: ESH

...

Vendor Unique Element 80-ESH: (ESH HUB)
Element Status         Status Bytes  Status Descriptions
  1 [ESH A]    : OK                01,00,00,03  
  2 [ESH A]    : OK                01,00,00,03  

Vendor Unique Element 84-ESH: (Power Ctrl)
Element Status         Status Bytes  Status Descriptions
  1: CRITICAL          02,86,00,00

  • 电源控制状态为 "incritical - power control fault detected command" environment status"

示例:

Channel: 12b Shelf: 1 Shelf Serial Number: OPS67734221717E
Shelf product id: DS14-Mk4-FC
Module A Serial Number: IMS6981331F5A74  Firmware rev: 14
Module B Serial Number: IMS6981331F5C7B  Firmware rev: 14
Controller A boot time: 2738 days 4 hrs 5 mins 11 secs
Controller B boot time: 2741 days 19 hrs 43 mins 31 secs
Power control state: critical - power control fault detected
Last power control completion status: inconsistent drive status
Timestamp: Sun Jun 28 14:20:44 CST 2020

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.