跳转到主内容

IOM12E 和 PSU 缺少磁盘,风扇和温度错误

Views:
8
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • AFF A220
  • FAS2750
  • FAS2720
  • IOM12E

问题描述

  • 一个或两个路径中缺少磁盘
    • 如果两个路径都缺少驱动器、则两个节点可能会重新启动、并且无法启动
  • 物理磁盘重新就位后、两个节点均关闭。
  • sysconfig -A 输出中缺少一个IOM12E模块:
Shelf 0: DS224-12 Firmware rev. A: ---- IOM12E B: 0220
  • 意外重新启动IOM12E。磁盘架日志消息示例:
Thu Jan 1 00:00:00 1970 ( 0+00:00:00.497); 02000027; U?; HAL; hal; 04; NDU Data Invalid.
Thu Jan 1 00:00:00 1970 ( 0+00:00:00.497); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 1-Cold boot

Sun Dec 31 03:04:33 +0900 [Node-01: storlog_admin: sla.shelf.mod.reboot.unexp:error]: Unexpected reboot event reported by module A in shelf: 0b.00.99.0, log: Thu Jan  1 00:00:00 1970 (    0+00:00:00.474); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 5-Crash reset
Sun Dec 31 03:04:33 +0900 [Node-01: storlog_admin: sla.shelf.message:debug]: params: {'type': 'SEVERITY', 'log': 'Thu Jan  1 00:00:00 1970 (    0+00:00:00.681); 0200013D; U?; HAL; hal; 02; Failure info:EXT NMI Handler'}

  • EMS环境错误示例:
Thu Apr 08 06:12:57 +0000 [node_name: dsa_worker2: ses.status.electronicsWarn:error]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b environmental monitoring warning for SES electronics 1: not installed. This module is on the rear of the shelf at the top left.
Thu Apr 08 06:12:57 +0000 [node_name: dsa_worker2: ses.status.procCplxError:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b Processor Complex error for Processor Complex 1: PCM on partner not installed This module is on the unknown location.
Mon Apr 12 08:17:00 +0000 [node_name: dsa_worker4: ses.status.temperatureWarning:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0a temperature warning for Temperature sensor 11: not operating. Current temperature: 49 C (120 F). This module is on the rear of the shelf at the top left, on shelf module A.
Mon Apr 12 08:17:00 +0000 [node_name: dsa_worker4: ses.status.temperatureWarning:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0a temperature warning for Temperature sensor 12: not operating. Current temperature: 35 C (95 F). This module is on the rear of the shelf at the top left, on shelf module A.
Thu Apr 22 08:40:42 +0000 [node_name: dsa_worker3: ses.status.ModuleError:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0a SAS expander error for SAS shelf electronics 1: critical status. This module is on the rear of the shelf at the top left, on shelf module A.
Thu Apr 22 10:17:28 +0000 [node_name: dsa_worker5: ses.status.psWarning:error]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b power warning for Power supply 1: not installed. This module is on the rear of the shelf at the bottom left.
Thu Apr 22 10:17:28 +0000 [node_name: dsa_worker5: ses.status.psWarning:error]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b power warning for Power supply 2: not installed. This module is on the rear of the shelf at the bottom right.
Thu Apr 22 10:27:50 +0000 [node_name: dsa_worker5: ses.status.temperatureWarning:alert]: DS224-12 (S/N SHFNC0123456789) shelf 0 on channel 0b temperature warning for Temperature sensor 14: not installed or failed. Current temperature: 28 C (82 F). This module is on the rear of the shelf at the top right, on shelf module B.
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.