跳转到主内容

DS4246 磁盘架状态非严重情况

Views:
63
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

DS4246

问题描述

non-critical condition 对于 DS4246 磁盘架,这两个 HA 节点均为指示节点。

  1. EMS 日志用于指示 Power supply 3: normal status 非现有 PSU 。
  2. 环境状态指示 _NO_PSN_PRESENT_ 非现有 PSU 。
  3. storage show fault 指示 OK 非现有 PSU 的状态。
  4. 环境状态显示空磁盘架托架的编号 16
  5. storage show fault 指示 NONCRITICAL 空磁盘架托架的状态 16

 

EMS
 

Mon Jun 21 07:11:51 KST [EMR:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0a power supply information for Power supply 3: normal status.
Mon Jun 21 07:11:51 KST [PACS:ses.status.psInfo:info]: DS4246 (S/N xxxxxxxxxxxxxxx) shelf 3 on channel 0b power supply information for Power supply 3: normal status.

 

< 环境状态 >


Channel: 0a
Shelf: 3
SES device path: local access: 0a.03.99
Module type: IOM6; monitoring is active
Shelf status: non-critical  condition
SES Configuration, shelf 3:
logical identifier=0x500a0980083d0635
vendor identification=NETAPP
product identification=DS4246
product revision level=0191
Vendor-specific information:
Product Serial Number: xxxxxxxxxxxxxxx

Power Supply installed element list: 1, 3, 4; with error: none
Power Supply information by element:
 [1] Serial number: xxxxxxxxxxxxxxx  Part number: 114-00087+G0
Type: 9E
Firmware version: 0208  Swaps: 0
 [2] Serial number: <N/A> Part number: <N/A>
Type: <N/A>
Firmware version: <N/A> Swaps: 0
 [3] Serial number: NO_PSN_PRESENT_  Part number: PPP-PPPPP+XX  
Type: 00
Firmware version: 0000  Swaps: 0
 [4] Serial number: xxxxxxxxxxxxxxx  Part number: 114-00087+G0
Type: 9E
Firmware version: 0208  Swaps: 0
...
Shelf mapping (shelf-assigned addresses) for channel 0a:
Shelf   0:  23  22  21  20  19  18  17  16  15  14  13  12  11  10   9   8   7   6   5   4   3   2   1   0
Shelf   1:  23  22  21  20  19  18  17  16  15  14  13  12  11  10   9   8   7   6   5   4   3   2   1   0
Shelf   2:  23  22  21  20  19  18  17  16  15  14  13  12  11  10   9   8   7   6   5   4   3   2   1   0
Shelf   3: XXX XXX XXX XXX XXX XXX XXX  16 XXX XXX XXX  12  11  10   9   8   7   6   5   4   3   2   1   0  
Shelf   4: XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX  12  11  10   9   8   7   6   5   4   3   2   1   0

 

< 存储显示故障 >


Disk Elements:
Element Status          Status Bytes  Status Descriptions

11 [Bay 11]: OK         01,0B,00,00
12 [Bay 12]: OK         01,0C,00,00
13 [Bay 13]: NOT INSTALLED    05,0D,00,00
14 [Bay 14]: NOT INSTALLED    05,0E,00,00
15 [Bay 15]: NOT INSTALLED    05,0F,00,00
16 [Bay 16]: NONCRITICAL     03,10,00,00
17 [Bay 17]: NOT INSTALLED    05,11,00,00
18 [Bay 18]: NOT INSTALLED    05,12,00,00
19 [Bay 19]: NOT INSTALLED    05,13,00,00
20 [Bay 20]: NOT INSTALLED    05,14,00,00
21 [Bay 21]: NOT INSTALLED    05,15,00,00
22 [Bay 22]: NOT INSTALLED    05,16,00,00
23 [Bay 23]: NOT INSTALLED    05,17,00,00

Power Supplies:
Element Status      Status Bytes  Status Descriptions
1: OK         01,00,00,A0   RQSTED ON
2: NOT INSTALLED    05,00,00,20
3: OK         01,00,00,A0  RQSTED ON
4: OK         01,00,00,A0   RQSTED ON

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.