由于布线配置不正确、报告了ClusterSwitchConnectivity _Alert
适用场景
- ONTAP 9
- FAS/AFA系统
- 所有集群网络交换机
问题描述
- 事件日志中会显示以下警报:
[Node-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConnectivity_Alert , Alerting Resource = Node-01 raised by monitor ethernet-switch
[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterSwitchConnectivity_Alert[Node-01].
- 的输出
system health alert show
显示以下详细信息:
::> system health alert show
Node: Node-01
Alert ID: ClusterSwitchConnectivity_Alert
Resource: Node-01
Severity: Major
Indication Time: Sat Feb 17 02:00:36 2024
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, Node-01 might lose access to the cluster.
- 交换机运行状况降级、原因是:
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok