在单个端口上收到 CRC 错误
适用场景
- FAS2552
- SFP-H10GB-CU3M 直连铜缆( DAC )
- 光纤扩展器( FEX )
- Cisco Nexus 5000 交换机
问题描述
- 存储每小时报告以下消息:
vifmgr.cluscheck.crcerrors: Port
on node
is reporting a high number of observed hardware errors, possibly CRC errors.
- 这一点也反映在 IFstat 命令的输出中:
Cluster::> system node run -node <node name>
-command ifstat
-- interface e0d (18 days, 14 hours, 50 minutes, 56 seconds) --
RECEIVE
Total frames: 924m | Frames/second: 575 | Total bytes: 3957g
Bytes/second: 2460k | Total errors: 8643k | Errors/minute: 322
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 8209k
Non-primary u/c: 0 | CRC errors: 8643k | Runt frames: 0
Long frames: 0 | Length errors: 394 | Alignment errors: 0
No buffer: 0 | Pause: 0 | Jumbo: 517m
Noproto: 0 | Bus overruns: 0 | LRO segments: 20631m
LRO bytes: 2573g | LRO6 segments: 0 | LRO6 bytes: 0
Bad UDP cksum: 0 | Bad UDP6 cksum: 0 | Bad TCP cksum: 0
Bad TCP6 cksum: 0 | Mcast v6 solicit: 0
- 将缆线从 FEX 移至 Nexus 交换机时,问题描述仍存在。
- 将缆线从同一个 Nexus 交换机移动到另一个存储端端口时,问题描述将遵循以下说明。