问题描述

  • 事件日志报告物理和/或逻辑端口上的硬件错误。

[node-01: vifmgr: vifmgr.cluscheck.crcerrors]: Port a0b on node node-01 is reporting a high number of observed hardware errors, possibly CRC errors
[node-02: vifmgr: vifmgr.cluscheck.crcerrors]: Port e0d on node node-02 is reporting a high number of observed hardware errors, possibly CRC errors
[node-02: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e0d on node node-02 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped)
[node-02: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: CRC Errors Detected - High CRC errors detected on port e0d node node-02

  • ifstat 如果ONTAP 收到错误、则输出将显示CRC错误。
  • 重新 安装缆线/SFP后、受影响 ifstat -z 节点上的问题描述仍然存在。

RECEIVE
 Total frames:   36418m  | Frames/second:   23646  | Total bytes:       179t
 Bytes/second:      116m | Total errors:      170k | Errors/minute:    7
 Total discards:      0  | Discards/minute:     0  | Multi/broadcast:  1686k
 Non-primary u/c:     0  | CRC errors:       159k | Long frames:      0

  • 在交换机端口或客户端上可能会出现 CRC 错误,并且可能会因数据包丢失而出现延迟

2022-03-20T17:39:36.443Z cpu36:2098075)WARNING: ScsiDeviceIO: 1498: Device naa.600a09803830574c4d5d53ddf26c4543 performance has deteriorated. I/O latency increased from average value of 18171 microseconds to 1816780 microseconds.

 

要记住的要点:

许多交换环境都使用直通交换、而不是存储和转发交换、因为其速度较快

  • 这意味着故障硬件可能不在直接连接的链路上
  • CRC可能发生在上游
  • 对于 ifstat CRC错误、此值在中显示为非零值
  • 如果虚电路为零但交换机具有虚电路、则可能会传输问题、但ONTAP未发现错误

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.