升级到固件NA02/NA04及更高版本后、某些磁盘会在EMS中报告"recovered error"消息
适用场景
- 运行固件版本NA02/NA04及更高版本的磁盘。
- 型号与以下列表匹配的磁盘:
部件号 sysconfig–A输出 容量 在固件版本中引入 x/SP-421-R5 X421_HCOBE450A10 450 GB NA02 x/SP-422-R5 X422_HCOBE600A10 600 GB NA02 x/SP-423-R5 X423_HCOBE900A10 900 GB NA02 x/SP-486-R5 X486_HCOBE450A10 450 GB NA02 x/SP-487-R5 X487_HCOBE600A10 600 GB NA02 x/SP-488-R5 X488_HCOBE900A10 900 GB NA02 x/SP-425-R5 X425_HCBEP1T2A10 1.2 TB NA02 x/SP-489-R5 X489_HCBEP1T2A10 1.2 TB NA02 x/SP-422A-R5
X422_HCBFE600A10
600 GB
NA04
x/SP-423A-R5
X423_HCBFE900A10
900 GB
NA04
x/SP-425A-R6
X425_HCBFE1T2A10
1.2 TB
NA04
x/SP-426A-R6
X426_HCBFE1T8A10
1.8 TB
NA04
x/SP-417A-R6
X417_HCBFE900A10
900 GB
NA04
x/SP-427B—R6
X427_HCBFE1T8A10
1.8 TB
NA04
x/SP-487A-R5
X487_HCBFE600A10
600 GB
NA04
x/SP-488A-R5
X488_HCBFE900A10
900 GB
NA04
x/SP-489A-R6
X489_HCBFE1T2A10
1、2 TB
NA04
x/SP-490A-R6
X490_HCBFE1T8A10
1.8 TB
NA04
x/SP-495A-R6
X495_HCBFE900A10
900 GB
NA04
x/SP-341A-R6
X341_HCBFE900A10
900 GB
NA04
x/SP-342A-R6
X342_HCBFE1T2A10
1.2 TB
NA04
x/SP-343A-R6
X343_HCBFE1T8A10
1.8 TB
NA04
问题描述
对于某些磁盘型号、将固件升级到版本NA02或更高版本后、某些磁盘可以在EMS中启动类似于以下内容的日志记录消息:
Mon Jun 17 12:47:11 CET [node:disk.ioRecoveredError.retry:info]: Recovered error on disk 1c.10.0: op 0x28:68cb85b0:0008 sector 255 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 94 94) (7) [NETAPP X423_HCOBE900A10 NA02] S/N [WWXXYYZZ]
Mon Jun 17 13:12:16 CET [node:disk.ioRecoveredError.retry:info]: Recovered error on disk 1c.10.0: op 0x28:68cb85b0:0008 sector 255 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 9d 9d) (7) [NETAPP X423_HCOBE900A10 NA04] S/N [WWXXYYZZ]