跳转到主内容

由于多个DIMM处于警告低重新分配状态、AFF a700s将重新启动

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009259337</a>
Last Updated:

适用场景

  • AFF a700s
  • BMC固件版本1.89和1.91

问题描述

  • 当DIMM不断报告警告低阈值报告时、节点重新启动。
    Wed Apr 20 19:19:39 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm G0 Temp is warning low (16 C).
    Wed Apr 20 19:25:39 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm A1 Temp is warning low (16 C).
    Wed Apr 20 19:25:39 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm G1 Temp is warning low (16 C).
    Wed Apr 20 19:26:39 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm A0 Temp is warning low (16 C).

    Wed Apr 20 19:27:38 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm B0 Temp is warning low (16 C).
    Wed Apr 20 19:45:39 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm H0 Temp is warning low (16 C).
    Wed Apr 20 19:59:39 -0700 [node1: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: Dimm B1 Temp is warning low (16 C).
  • 然后、节点崩溃、出现温度过低。
    Sun May 08 15:56:17 -0700 [node1: env_mgr: callhome.chassis.undertemp:EMERGENCY]: Call home for CHASSIS UNDER TEMPERATURE SHUTDOWN
  • 通过ASUP和系统管理器报告的崩溃将记录为温度过高。
  • 检查节点上的系统传感器时、所有其他传感器报告的温度范围与DIMM相同。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.