适用场景

  • FAS2720
  • ONTAP 9

问题描述

  • EMS中出现"netf.uncorEccError:EMERCY"错误、导致e0d端口处于停机状态。

 Thu Jan 04 08:21:50 +0900 [node-02: intr: netif.uncorEccError:EMERGENCY]: Unrecoverable ECC error on network interface e0d.
 Thu Jan 04 08:21:51 +0900 [node-02: intr: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
 Thu Jan 04 08:21:51 +0900 [node-02: intr: net.ifgrp.lacp.link.inactive:error]: ifgrp a1b, port e0d has transitioned to an inactive state. The interface group is in a degraded state.
 Thu Jan 04 08:21:54 +0900 [node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node-02, port e0d.

  • 已根据dmesg日志确认通过重新启动节点进行端口恢复。

[15891540] Jan 04 08:21:50 [node-02:netif.uncorEccError:EMERGENCY]: Unrecoverable ECC error on network interface e0d.
[15891554] e0d: ixgbe_ioctl: Port encountered ECC error. Reboot node to recover

  • e0d和e0f归类为IFRP、在它们之间交换缆线不会导致e0d建立链路。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.