适用场景

  • ONTAP 9.8 及更高版本:
  • SnapMirror 业务连续性( SM-BC )

问题解答

  • 您不能暂停或中止SnapMirror业务连续性(SM-BC)/"自动故障转移"关系。
  • 唯一可用的选项为更新、故障转移或删除。
  • 如果计划重新定位主集群、则必须考虑"计划内故障转移"。否则、调解器将协商无中断故障转移。
  • 如果二级集群脱机、则通过二级集群的所有路径都将无法供主机多路径软件使用、因此、故障转移的能力将受到影响。
  • 如果 必须重新定位主集群和二级集群、请先关闭二级集群、然后再关闭主集群。 
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.